Definition
A code set representing the area in which the change is located on the electrocardiogram (ECG).
Representation
Data Type | Number |
---|---|
Format | N |
Maximum character length | 1 |
Values
Value | Meaning | Start Date | End Date | |
---|---|---|---|---|
Permissible Values | 1 | Inferior leads: II, III, aVF | ||
2 | Anterior leads: V1 to V4 | |||
3 | Lateral leads: I, aVL, V5 to V6 | |||
4 | True posterior: V1 V2 | |||
Supplementary Values | 9 | Not stated/inadequately described |
Comments
Guide for use:
CODE 4 True posterior: V1 V2
True posterior is relevant only for tall R waves.
References
Related content
Relation | Count |
---|---|
Data Elements implementing this Value Domain | 1 |